We are the Only Company to Pre-burn all lamps! Each Receive 3, 12 hour burn cycles to ensure the cermets seal is seated properly. This is 100% Needed as there is a High initial failure rate. If this is done you are sure to have a full life from your lamp. |
US Customers
$10.00 Flat Rate Shipping on any QTY Lamp Orders* If ordering a ballast also we have to charge a Little More. |
| 250 Watt Horizontal CDM250S50/HOR/4K/ALTO $51.00 USD | 250 Watt Vertical CDM250S50/V/O/4K/ALTO $52.00 USD | 400 Watt Horizontal CDM400S51/HOR/4K/ALTO $53.00 USD | 400 Watt Vertical CDM400S51/V/O/4K/ALTO $52.00 USD |
| Don't have a
Ballast? May We Recommend A Ballast Kit. |
|
| 250 Watt HPS Ballast Kit (Price $49.00 USD | 400 Watt HPS Ballast Kit Price $54.00 USD |
Want to Know more about CMH? Check out our CMH FACT PAGE
|
Philips MasterColor® Ceramic Metal Halide
HPS-Retro White™ featuring ALTO® Lamp Technology Replace yellow light with crisp, bright white light with
just a simple twist! |
|
|
![]()
|
|
Colors are brighter and more vivid under MasterColor®
Vertical and Horizontal Operation Lamps are available The Ceramic Discharge Arc Tube is More Robust than the
Traditional Quartz Arc Tube Utilized in Metal Halide Lamps Witch
provides. Patented "Coil Design" |
|
|
|
|
|
Indoor facilities have made the switch! …from yellow HPS Lamps to MasterColor® HPS-Retro White™ The Boeing Plant in Wichita, Kansas utilized Standard HPS bulbs (left) and were replaced with MasterColor HPS-Retro White bulbs (Right) in July, 2001. Photos courtesy of Boeing. ![]()
"The HPS-Retro White lamps allowed us to change HPS fixtures to white
light without replacing the fixtures. The 17% reduction in foot-candles
has been compensated by the brighter light. The brighter lamps have
eliminated shadows. HPS-Retro White has provided another tool for better
lighting by just changing the lamp." |
|
|
Indoor facilities have made the switch! (Cont) ![]() |
|
|
Outdoor lighting Has made the switch! …from yellow HPS Lamps to MasterColor® HPS-Retro White™ Outdoor Parking lot utilized standard HPS bulbs (Below) were replaced with MasterColor HPS-Retro White bulbs (right). Photos courtesy of Jeff MacWright. ![]() |
|
|
|
|
|
Phlips MasterColor HPS-Retro White Featuring ALTO
Lamp Technology Electrical, Technical, & Ordering Information ~ Currently there is NO Cross To other MFR at this time. ~ All Data Subject to change without Notice. PDF Data Sheet |
||||||||||||||
|
Horizontal Operation Only (Bulb is Base Sideways) You Sleep Horizontally |
||||||||||||||
|
Product Number |
Ordering Code |
Nom. Watts |
Bulb | Base |
Std. Pkg. Qty. |
ANSI |
LCL (In) |
MOL (In) |
Color Temp (Kelvin) |
CRI |
Rated Avg. Life (Hrs)1 |
Approx Initial Lumens2,3 |
Approx Mean Lumens2,3 |
|
| 14649-B | CDM250S50/HOR/4K/ALTO | 250 | ED18 |
Mog E39/E40 |
12 | S50/M168/O | 5.75 | 9.75 | 4000K | 85 | 20,000 | 20,500 | 16,400 | |
| 14650-6 | CDM4000S50/HOR/4K/ALTO | 400 | ED18 |
Mog E39/E40 |
12 | S51/M169/O | 5.75 | 9.75 | 4000K | 85 | 15,000 | 34,800 | 29,600 | |
|
Vertical Operation Only (Bulb Hangs Base Up or Base Down) You Stand Vertically. |
||||||||||||||
|
Product Number |
Ordering Code |
Nom. Watts |
Bulb | Base |
Std. Pkg. Qty. |
ANSI |
LCL (In) |
MOL (In) |
Color Temp (Kelvin) |
CRI |
Rated Avg. Life (Hrs)1 |
Approx Initial Lumens2,3 |
Approx Mean Lumens2,3 |
|
| 13093-0 | CDM250S50/V/O/4K/ALTO | 250 | ED18 |
Mog E39/E40 |
12 | S50/M168/O | 5.75 | 9.75 | 4000K | 85 | 20,000 | 20,500 | 16,400 | |
| 13094-B | CDM400S51/HOR/4K/ALTO | 400 | ED18 |
Mog E39/E40 |
12 | S51/M169/O | 5.75 | 9.75 | 4000K | 85 | 20,000 | 34,800 | 27,840 | |
d
| Don't have a
Ballast? May We Recommend A Ballast Kit. |
|
| 250 Watt HPS Ballast Kit (Price $49.00 USD | 400 Watt HPS Ballast Kit Price $54.00 USD |
d
| R RECOMMENDED WARNINGS, CAUTIONS, AND OPERATING INSTRUCTIONS m WARNING: "These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available." This lamp complies with FDA radiation performance standard 21 CFR subchapter J. (USA:21CFR 1040.30 Canada: SOR/ DORS/80-381). If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous short wave ultraviolet radiation. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause glass to fly if the envelope is struck. WARNING: The arc-tube of metal halide lamps are designed to operate under high pressure and at temperatures up to 1000º C and can unexpectedly rupture due to internal or external factors such as a ballast failure or misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment. If such a rupture were to happen, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE. These lamps are designed to retain all the glass particles should an arc tube rupture occur. The following operating instructions are recommended to minimize these occurrences. RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture. This lamp contains an arc tube with a filling gas containing Kr-85 and is distributed by Philips Lighting Company, a division of Philips Electronics North America Corporation, Somerset, New Jersey, 08875. CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE RESULTING FROM AN ARC-TUBE RUPTURE THE FOLLOWING LAMP OPERATING INSTRUCTIONS MUST BE FOLLOWED: LAMP OPERATING INSTRUCTIONS: 1) RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture. 2) Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards. 3) Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by ballast manufacturer. A. Operate lamp only within specified limits of operation. B. For total supply load refer to ballast manufacturers electrical data. 4) Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks or damage. 5) If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of the bulb glass. 6) Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat. 7) Time should be allowed for lamps to stabilize in color when turned on for the first time. This may require several hours of operation, with more than one start. Lamp color is also subject to change under conditions of excess vibration or shock, and color appearance may vary between individual lamps. 8) Lamps may require 10 to 20 minutes to re-light if there is a power interruption. 9) Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the contents or fragments. |
| 250 Watt Horizontal CDM250S50/HOR/4K/ALTO $51.00 USD | 250 Watt Vertical CDM250S50/V/O/4K/ALTO $52.00 USD | 400 Watt Horizontal CDM400S51/HOR/4K/ALTO $53.00 USD | 400 Watt Vertical CDM400S51/V/O/4K/ALTO $52.00 USD |
| Don't have a
Ballast? May We Recommend A Ballast Rebuild Kit. |
|
| 250 Watt HPS Ballast Kit (Price $49.00 USD | 400 Watt HPS Ballast Kit Price $54.00 USD |
© Advanced Technology Solutions, LLC ~ Lighting Division, all rights protected.
Any other Images Trademarks & Copyrighted Material used IS the property of their respective owners.
Warning all Images and Cell/Tables have been Embedded with our Information
Prevent Competitors from Steeling Information we worked compiled.
Customers are Fully Authorized to Post our information in Public Forums
As long as we are Given Credit or Linked by Poster.